Created with Pixso. Bipolar Electrosurgical Generator 400W Pure Cut 6 Modes Endoscope Compatible

Bipolar Electrosurgical Generator 400W Pure Cut 6 Modes Endoscope Compatible

Nom De La Marque: Bestran
Numéro De Modèle: BT-ES07
MOQ: 1 pièce
Prix: USD 390 PC
Délai De Livraison: 3-5 jours
Conditions De Paiement: T/T, Western Union, MoneyGram
Informations détaillées
Lieu d'origine:
Chine
Certification:
CE
Produit:
Générateur électrochirurgical bipolaire
Pouvoir:
400W
Modes fonctionnants:
6
Coupe pure:
1W ~ 350W (max. 400W, charge 500 Ω);
Mélange de coupe 1:
1W ~ 250W (charge 500 Ω);
Blend Cut 2::
1W ~ 200W (charge 500 Ω);
EndU Cut::
99% (charge 500 Ω);
Pulvériser de la coagulation:
1W ~ 80W (charge 500 Ω);
Décrire la coagulation:
1W ~ 120W (charge 500 Ω);
fonction de coupe bipolaire:
Option
Détails d'emballage:
46*42*30cm, 11KG
Capacité d'approvisionnement:
500pcs par mois
Mettre en évidence:

400W bipolar electrosurgical generator

,

endoscope compatible electrosurgical generator

,

6 modes bipolar surgical equipment

Description de produit

Bipolar Electrosurgical Generator 400W Pure Cut 6 Modes Endoscope Compatible


Bipolar Electrosurgical Generator Features:

  • This advanced bipolar electrosurgical generator delivers exceptional surgical precision with 400W pure cut power and 6 specialized operating modes (including blend cuts, spray coagulation, and soft coagulation), providing unparalleled versatility for various surgical procedures.
  • Featuring dual control options (foot pedal and handswitch) and endoscope compatibility, the unit enables seamless integration with endoscopic systems for polypectomy and other minimally invasive surgeries.
  • With a maximum bipolar output of 100W and complete accessory set including bipolar forceps and disposable electrodes, this generator ensures reliable performance in both open and endoscopic procedures while maintaining patient safety through precise energy delivery.


Bipolar Electrosurgical Generator Spefication:


Pure cut

1W~350W (Max. 400W, load 500 Ω);
A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasis. (No-focus precision cutting, 100% cutting.)

Blend cut 1

1W~250W (load 500 Ω);
Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode. (Superficial focal gamma accurate cutting 80% cutting, 20% coagulation.)

Blend cut 2

1W~200W (load 500 Ω);
The mode is used for vaporization of prostatic tissue or any fat tissue. The higher output wattage gives fast cutting effect of the tissue. (60% cutting, 40% coagulation.)

ENDU Cut

99% (load 500 Ω);
The mode is used to automatically controlled cut system to reduce the complication rate of endoscopic sphincterotomy (EST) and serum hyperamylasemia after EST compared to the conventional blended cut mode.

Spray coagulation

1W~80W (load 500 Ω);
Spray output is made for direct coagulation at the tissue with spark. Above spark does not give any cutting effect as its CREST FACTOR is high. (Massive coagulation)

Desicate coagulation

1W~120W (load 500 Ω);
Coagulation in which the active electrode is in direct contact with the tissue is referred to as desiccation and is the type of coagulation used in most surgeries it ensures pinpoint desiccation with less destruction of peripheral tissue.

Standard bipolar coagulation

1W~70W (load 100 Ω);
BI-COAG - For highly precise control over coagulation process and privations of carbonization.

Power consumption of the whole machine: ≤ 1100VA. (cut function 350W);



Bipolar Electrosurgical Generator Type:


The output of this machine is fully suspended, with two independent and isolated CF type anti-defibrillation application parts (Monopolar and Bipolar), Non-AP,Non-APG type common equipment, and 220V ± 10% or 110V ± 10% network power supply.


Bipolar Electrosurgical Generator Function:


The 416KHz (± 10%) high frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut 1, blend cut 2; Monopolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.

  • Full-function automatic power compensation.
  • The high-frequency generator has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope, laparoscope and other endoscopes.
  • Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.
  • Patient circuit bipolar electrode plate contact quality detection system.
  • Monopolar output can be controlled either by hand or foot, and monopolar/bipolar automatic output.
  • This machine has a power-off protection circuit, which can memorize the output set value of each function in real time.
  • Remote fault diagnosis.
  • Human voice alarm function
  • Passed EMC test.

Bipolar Electrosurgical Generator  Usage

An electrosurgical unit (or high-frequency electrotome) is used in various medical settings for cutting tissue and controlling bleeding. Common places include:

  1. Hospital Operating Rooms: For a wide range of surgeries, from general to specialized procedures.

  2. Outpatient Surgery Centers: For minor operations and day surgeries.

  3. Dermatology and Plastic Surgery Clinics: For precise tissue removal and cosmetic procedures.

  4. Veterinary Clinics: For surgical procedures on animals.